Context

CIC and VT Resistance could retain per-file derived values from different control settings, and CIC could sample outside the recorded time range while displaying a delay without units.

Decision and rationale

Treat analysis controls as one batch contract and recompute every file before display/export so rows cannot silently mix stale and current parameters.

Changes

User and data impact

Batch rows now represent one consistent area, delay, pulse-detection, resistance-window, and voltage-mode configuration. Invalid delay choices fail instead of extrapolating a misleading value.

Compatibility and migration

CIC CSV adds trailing Area_cm2 and Delay_us columns. Existing columns keep their names and order; VT Resistance exports remain schema-compatible.

Validation

Electrochem unit and GUI tests cover batch recomputation, display units, out-of-range handling, and export-time refresh.

Evidence

The guarded calculations and export builders are app-owned. Commit 67ea2286 introduced the consistent batch-analysis and export behavior.

Known limitations and follow-up

The fix enforces internal batch consistency but does not choose scientifically appropriate area, delay, or resistance windows for the user.