LabKit MATLAB Workbench

app

ECG Print

ECG Print reads a wearable recording, filters one channel, detects beats, builds event-centered segments and a representative template, and reports signal quality over time. It can export the segment measurements and a printable waveform image.

Open ECG Print

From the LabKit launcher, select ECG Print and choose Open. From a source checkout, run:

labkit_ECGPrint_app

Supported Inputs

Choose Open recording to load a MAT, CSV, TXT, or TSV biosignal file. MAT files can contain a supported timetable or recording structure. Delimited text files can be detected automatically or parsed with the controls under Import Parsing.

For a difficult text file, choose Preview file header, then set:

Choose Parse / refresh file after changing import settings. The app reports the detected channels and lets you select one for analysis.

The recording is saved as a portable project source. Older projects are upgraded on load.

Project And Session State

ECG Print stores only durable workflow state in its project file:

Decoded recordings, signal arrays, events, segments, templates, measurements, header previews, and plot models are transient session data. They are rebuilt from the recording and durable parameters when a project is opened. This keeps saved projects portable and avoids duplicating large waveform caches.

Analyze ECG

  1. Open and parse a recording.
  2. Select a channel and, if needed, set the start and end of the time region. When the end is not greater than the start, the full signal is used.
  3. Set the bandpass range and peak method.
  4. Set minimum peak distance, segment half-window, template count, and smoothing count.
  5. Choose Analyze current ROI.
  6. Review the four plots: waveform and peaks, template-noise RMS, template SNR, and the template with either a residual band or individual segments.

The filter is applied to the full selected channel before the time region is cropped. This reduces boundary artifacts at the region edges.

The Files + Analysis tab keeps the workflow in five ordered sections: Recording, Import Parsing, Channel + ROI, Signal Processing + SNR, and Exports. Bounded numeric settings use paired spinner-and-slider controls. Summary + Results contains the analysis summary and file-header preview, while Log records the current session workflow. The ECG Preview workspace keeps four vertically stacked time-series axes available on every tab.

Analysis Parameters

ParameterDefaultMeaning
Fallback sample rate2000 HzUsed only when import cannot derive time spacing
Bandpass0.5 to 40 HzApplied before peak detection; the upper cutoff is kept below 45% of sample rate
Peak methodQRS streamingQRS streaming, Pan-Tompkins, or local peaks
Peak distance0.28 sMinimum interval between accepted detections
Segment half-window0.7 sData retained before and after each event
Template top N30Number of best segments used to build the template
Smooth beats15Smoothing span used in exported per-segment trends
Template plotTemplate + residual bandAlternative view is template plus individual segments

Peak polarity is selected automatically. The default detector threshold is 2.8 standard deviations inside the app calculation.

Output Files

Export segment SNR CSV writes ecg_segment_snr.csv and a matching ecg_segment_snr.labkit.json manifest. The CSV contains per-segment measurements and smoothed trends.

Export waveform PNG writes ecg_waveform.png and ecg_waveform.labkit.json. The manifest records the source, import and analysis settings, output identity, event count, segment count, and summary.

Analyze A Signal In MATLAB Code

[recording, status] = labkit.biosignal.readRecording("ecg.csv");
assert(status.ok, status.message)

signal = labkit.biosignal.getChannel(recording, 1);
cache = struct("signal", signal);
parameters = struct( ...
    "lowCut", 0.5, ...
    "highCut", 40, ...
    "roiStart", 0, ...
    "roiEnd", 0, ...
    "peakMethod", "QRS streaming", ...
    "peakDistance", 0.28, ...
    "segmentWindow", 0.7, ...
    "templateTopN", 30);

cache = ecg_print.analysisRun.analyzeSignal(cache, parameters);

The returned cache contains the working and filtered signals, detected events, segments, template, and measurements. For a more customized pipeline, call labkit.biosignal.filterSignal, detectEcgPeaks, segmentByEvents, buildTemplate, and measureSegments directly.

Errors And Limitations