Syntax

records = labkit.thermal.readFiles(paths) records = labkit.thermal.readFiles(paths, opts) [records, report] = labkit.thermal.readFiles(paths, opts)

Description

Calls labkit.thermal.readFile for each path in input order. By default, the first unreadable file stops the operation. Set SkipInvalid to true when a batch should keep its readable records and return a failure entry for each skipped file.

Inputs

paths
Character vector, string array, or cell array of character vectors and strings. Empty strings are removed. Output record order follows the remaining input order.
opts
Optional scalar structure. See Options.

Options

AllowEmpty
Logical scalar. When true, an empty path list returns empty records and a zero-count report. When false, an empty list throws labkit:thermal:NoPaths. Default: true.
RequireExisting
Logical scalar forwarded to readFile. Default: true.
SkipInvalid
Logical scalar. When true, an unreadable file is added to report.failures and processing continues. When false, its exception is rethrown immediately. Default: false.
TemperatureCorrection
String scalar forwarded to readFile. Allowed values are "environment" and "planck-basic". Default: "environment".
progressFcn
Empty or a function handle called once before each read and again after it loads or is skipped. The callback receives a scalar structure with stage, index, count, path, and name. stage is "beforeRead", "afterRead", or "skipped". Default: [].

Outputs

records
Column structure array of successfully read thermal records. See labkit.thermal.readFile for the fields in each element.
report
Scalar structure. requested is the number of normalized paths; loaded and skipped are counts. failures is a structure array with path, name, identifier, and message for each skipped file.

Errors

In addition to readFile errors, throws labkit:thermal:InvalidOptions when opts or a callback is invalid and labkit:thermal:NoPaths when AllowEmpty is false and no usable path remains.

Typical Call

opts = struct("SkipInvalid", true, ...
"TemperatureCorrection", "environment");
[records, report] = labkit.thermal.readFiles(files, opts);
fprintf("Loaded %d of %d files.\n", report.loaded, report.requested)

Source